Instructions / Assembly

www.GhostControls.com
Made in China, Rev. 2017-07
CLONE / COPY BUTTON 2’S ID TO BUTTON 1’S (BUTTON 2 ALREADY CONTROLS THE GATE)
STEP NOTE
BUTTON(S) SEQUENCE
TO PRESS
LED/ALARM
AFTER PRESSING
DESCRIPTION
1
Press & hold LEARN
button on Remote for AT
LEAST 3 seconds until the
LED turns on
LED on Remote stays
Places remote transmitter into Learning mode.
2
Release the LEARN Button
LED remains
Remote is in Learning Mode.
3
Press and Release Button 2
LED should start
(2 flashes a sec)
Remote is sending button 2’s ID.
4
Press and Release Button 1
LED should go
Button 2’s ID is accepted by button 1. Both buttons should now work the same gate.
GENERATING A NEW TRANSMITTING KEY CODE
CAUTION
Please READ and PROCEED with CAUTION
Each GHOST CONTROLS
®
remote transmitter has a unique key code sequence. Once a new key sequence is generated, the previous key code is lost. The new key code
will need to be programmed or “learned” into the gate opener to control the gate.
STEP
LED/ALARM
BEFORE PRESSING
BUTTON(S) SEQUENCE
TO PRESS
LED/ALARM
AFTER PRESSING
DESCRIPTION
1
Press & hold
AND
simultaneously for 10 seconds
on Remote until the LED goes
LED on Remote goes
Tells the remote transmitter (Remote B) that you are going to generate a new code. Step 2 & 3 must be
completed within 5 seconds while the LED is lit.
2
Release
AND
3
Remote LED is
Press & release or
on Remote
LED goes The remote button pressed in this step is now generating a new code.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
This device may not cause harmful interference
This device must accept any interference received, including interference that may cause undesired operation.
WARNING G
Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
NOTE
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable pro-
tection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment o and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
Reorient or relocate the receiving antenna
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
Consult the dealer or an experienced technician for help.
WARNING: This product can expose you to chemicals including lead, which is known to the State of California to cause cancer.
For more information, go to www.P65Warnings.ca.gov