TROUBLESHOOTING
PROBLEM CAUSE SOLUTION
The machine does not turn
on when the key is turned.
Low battery.
Main fuse blown.
Check that the battery is
charged.
Replace the master 7,5A
fuse.
The brush does not rotate. Brush fuse blown.
Brush rotation enabling
switch not pressed
Replace the GREEN 30A
brush motor fuse.
Press the switch.
Aspirator does not work. Aspirator fuse blown.
Suction unit switch not
pressed.
Recovery tank full.
Replace the RED 40A fuse
for the suction unit’s motor.
Press the switch.
Empty, wash and clean the
tank and the probes.
The machine does not dry
well, leaving traces of water
on the floor.
Aspirator off.
Aspiration tube blocked.
Recovery tank full.
Squeegee rubber blades
worn.
Start up the aspirator.
Check and if necessary
clean the aspiration tube
that connects the squeegee
to the recovery tank.
Empty the recovery tank.
Replace or turn over the
squeegee rubber blades.
No water comes out. Tank empty.
Solenoid valve enabling
switch not pressed.
Tap turned off.
Filter blocked.
Solenoid valve does not
work.
Fill the tank.
Press the switch.
Open the tap
Clean the filter.
Call the technical support
service.