manual
GFI Network Server Monitor Configuring monitor functions • 61
• VB Function Parameters – In the parameters list, specify any
additional parameters required by this function. During check
execution these parameters will be automatically passed on to the
VB script in the order specified in the VB Function Parameters list.
To add a parameter, double click on the position/row where you
wish to add this additional parameter and specify the required
values in the parameters dialog. Parameter values can be
specified as a string, number or can be passed on through system
variables (e.g. %USERNAME%).
NOTE 1: Strings must always be specified within double quotes (“”)
e.g. “Mail Server”.
NOTE 2: You may make changes to the selected script file by clicking
on the ‘Edit script …’ button.
NOTE 3: The “Generic Secure Shell (SSH) Check” requires logon
credentials (i.e. username and password or Private Key file) to
connect (authenticate) and run SSH scripts on a remote Unix-based
target computer. These credentials must be specified from the ‘Logon
Credentials’ tab available in the properties of the relative check. For
more information on logon credentials, please refer to the ‘Logon
credentials’ section in the ‘Configuring GFI Network Server Monitor’
chapter.
OS Object Performance Counter
The OS Object Performance Counter establishes the performance of
an operating system object available on the target computer by
checking its properties.
Screenshot 53 - OS Object Performance Counter check parameters dialog