User manual
64 |G3 – Owner’s Manual
10.3 HI-HAT CALIBRATION
The hi-hat is the most complex instrument of a drum kit. It requires particularly good coordination between hardware
and software to produce the best playing results.
Proceed as follows to calibrate the hi-hat.
Press [12] [TRIGGER SET].
[Trigger
Set]
Press [F3] “HH-CALIB“.
[F3] HH-CALIB.
Press the Hi-Hat together with your foot and press [F2] “NEXT”.
[F1] NEXT
Open the Hi-Hat completely. Confirm the action by pressing the button [F1] “FINISH”.
[F1] FINISH
TRIGGER SET [F3]
Hi-Hat Calibration
1
2
3