1.2 Emergency measures in case of gas leakage
Always observe your own safety.
Hold your breath.
Aclothheldinfrontofthemouthandnosedoesnotprotectanddoesnotltertoxic
gases.
Extinguish open ames including smokers.
Breathe fresh air, eg. at the window.
Provide fresh air by opening windows and doors.
Thus, the concentration of gase in the air is rapidly reduced.
Turn o all gas sources.
Rescue victims with symptoms of intoxication in the fresh air.
Do not turn on or o electrical appliances, including telephones, doorbells and
the Tri-Gas Detector 230 V & 12 V.
Close the main gas stopcock.
With LPG this is usually directly at the gas tank.
Depending on the situation, call the gas supplier or the re brigade: 112
1.3 Warning steps
DANGER
Warnings against hazards that will result directly in death or serious
injuries in case of non-observance.
WARNING
Warnings against hazards that may result in death or serious injuries
in case of nonobservance.
CAUTION
Warnings against hazards that may result in injuries in case of non-
observance.
NOTICE
Warnings against hazards that may result in material damage in case of
non-observance.
1.4 Target group information
Activity Target group
Installation, repair, installation, disassembly Electric / gas experts
Operation, maintenance, storage,
transport, disposal
Consumers
Emergency measures Consumers, re department, paramedics
All work on the product must not be carried out by children or persons with
physically and / or mentally limited abilities.
2 Description and function
2.1 Tri-Gas Detector 230 V & 12 V
The product is made for detecting natural gas, city gas and cylinder gas leaks. It is inten-
ded for installation in homes, caravans and campers. The Tri-gas detector 230 V & 12 V
can be connected to a 12 V DC power source such as the on-board network of caravans
and motorhomes, but also via 230 V~ power supply to the domestic power grid, for exa-
mple in kitchens or garages. In addition to the visual and audible alarm, it has a self-test
function and is insensitive to organic liquids.
2.2 Operating elements and displays
1 Housing 2 Fault LED 3 Alarm LED
4 Power LED 5 Buzzer 6 Sensor openings
7 230 V~ power supply 8 12 V DC adapter
2.3 Technical specications
Device
Connection 230 V~ power supply | 12 V DC adapter
Power supply 230 V~, 50 Hz | 12 V DC ±5 %
Input power 1.5 W at alarm
1.0 W at detection
Installation height
Gas is heavier than indoor air,
Example: liqueed petroleum
gas (LPG): 0.15-0.30 m above
the ground
Gas is lighter than indoor air,
Example: natural gas, city gas:
0.15-0.30 m under the ceiling
Detector reach max. 6 m near the ceiling
max. 4 m near the oor
Sensivity at a concentra-
tion of 12 % of the lower
explosion limit
Propane 0.20 %
Butane
0.17 %
Methane 0.53 %
Detection threshold at
reaction time
50 ppm at 60-90 minutes
100 ppm at 10-40 minutes
300 ppm at <3 minutes
Recommended life time 5 years
Protection level IP20
optimal working space 0 °C ~ +50 °C | max. 95 % humidity
Signal volume @ 3 m 85 dB
Dimensions 75 x 75 x 45 mm
Cable length 230/12 V ~1.8 m
Mounting hole distance 45 mm
Weight 125 g