User's Manual

HANVON PENTECH CO., LTD
The information contained herein is the exclusive property of Hanvon Pentech Co., Ltd. and shall not be
distributed, reproduced, or disclosed in whole or in part without prior written permission of Hanvon Pentech
Co., Ltd. Page 14 of 15
11. Reliability test
This is for your reference only. The final Reliability test for
TP-101S01-H1S1-GT will be provided after we get final product
Test Conditions:
1. The Electromagnetic Touch Board should be inspected as regular functional
testing.
2. No condensing of water (moisture) is allowed on the Electromagnetic Touch
Board.
3. For environmental tests, temperature gradient is 15/hour.
4. The number for the test samples is 10 units.
Item
Test condition
Criterion
Operating
Environment
(1) High temperature 50 72hrs
(2) High humidity 90%, temperature 60 72hrs
(3) Low temperature 072 hrs
After changing the environment, condition is
brought back to normal (15 - 35, 25-75 %( RH).
Another one or more hours later, functional test is
performed.
No
malfunction
Storing
Environment
(1) High temperature 75 72hrs
(2) High humidity 85%, High temperature 75
72hrs
(3) Low temperature -10 72hrs
After changing the environment, condition is
brought back to normal (15 - 35, 25-75 %( RH).
Another one or more hours later, functional test is
performed.
No
malfunction
Package
Drop
(1) Height : 80cm
(2) Floor surface : Concrete
(3) Number of drops :
A corner of the bottom panel 1
An edge between bottom and end panels 1
An edge between bottom and side panels 1
An edge between side and end panels 1
All six panels 6
Total 10 drops
No
malfunction
Package
Vibration
(1) Z axis : 2G
(2) X and Y axis : 1G
(3) Frequency : 5200Hz Sweep
No
malfunction