11. Reliability test
( This is for your reference only. The final Reliability test for
TP-101S01-H1S1-GT will be provided after we get final product)
Test Conditions:
1. The Electromagnetic Touch Board should be inspected as regular functional
testing.
2. No condensing of water (moisture) is allowed on the Electromagnetic Touch
Board.
3. For environmental tests, temperature gradient is 15℃/hour.
4. The number for the test samples is 10 units.
Item
Test condition
Criterion
Operating
Environment
(1) High temperature 50℃ 72hrs
(2) High humidity 90%, temperature 60℃ 72hrs
(3) Low temperature 0℃72 hrs
After changing the environment, condition is
brought back to normal (15 - 35℃, 25-75 %( RH).
Another one or more hours later, functional test is
performed.
No
malfunction
Storing
Environment
(1) High temperature 75℃ 72hrs
(2) High humidity 85%, High temperature 75℃
72hrs
(3) Low temperature -10℃ 72hrs
After changing the environment, condition is
brought back to normal (15 - 35℃, 25-75 %( RH).
Another one or more hours later, functional test is
performed.
No
malfunction
Package
Drop
(1) Height : 80cm
(2) Floor surface : Concrete
(3) Number of drops :
A corner of the bottom panel 1
An edge between bottom and end panels 1
An edge between bottom and side panels 1
An edge between side and end panels 1
All six panels 6
Total 10 drops
No
malfunction
Package
Vibration
(1) Z axis : 2G
(2) X and Y axis : 1G
(3) Frequency : 5~200Hz Sweep
No
malfunction