SDS
Page 3 of 9
Issuing date: August 8, 2016
Remove containers from fire area if it can be done without risk.
Cool surrounding facilities, etc. with water spray.
Extinguish fire from upwind, and the fire extinguishing method should be appropriate to the situation in the surroundings.
Special actions for fire-fighters: Firefighters must wear self-contained breathing apparatus and full protective equipment.
Check whether the protective equipment is in good condition before use.
6. Accidental release measures
Personal precautions, protective equipment and emergency procedures: Use proper personal protective equipment as
indicated in Section 8.
Environmental precautions: Keep cleaning run-offs out of municipal sewers and open bodies of water. Comply with local
and national laws and regulations.
Methods and material for containment and cleaning up:
Small Spill:
If this battery ruptures, do not touch the battery directly.
Wear protective gloves and sweep up leakage carefully.
Label the waste containers and dispose it in a proper way.
7. Handling and storage
Precautions for safe handling:
Do not breathe vapors or fumes that may be evolved during processing.
Do not disassemble or burn batteries.
Do not squeeze or pierce batteries.
Do not put batteries into water.
Workers must wear proper protective equipment and must operate strictly according to relative rules.
Conditions for safe storage, including any incompatibilities:
Do not store near flame or incompatible materials.
Keep battery terminals insulated when in storage or transportation. The temperature in the storeroom must be controlled in a
proper range.
Avoid long-time direct contact of sunlight.
Incompatible substances or mixtures: Strong oxidizing agents, strong acids, strong bases, reducers and halogens.
Packing material: Blister card.
8. Exposure controls/personal protection
Occupational Exposure Limits:
Ingredients
OSHA PEL-TWA
ACGIH TLV-TWA
Sodium hydroxide (CAS: 1310-73-2)
2mg/m
3
2mg/m
3
Graphite (CAS: 7782-42-5)
15mppcf
2mg/m
3
Engineering Controls:
Use this product only in closed systems fully or with local exhaust ventilation.