Users Manual
Regulatory Module Integration Instructions
2.2 List of applicable FCC rules
This device complies with part 15.247 of the FCC Rules.
2.3 Summarize the specific operational use conditions
This module can be used in household electrical appliances as well as lighting equipment.
The input voltage to the module should be nominally 4.5~5.5 V
DC
,typical value 5.0V
DC
and
the ambient temperature of the module should not exceed 85°C.
This module using only two kind of antennas, with maximum gain is 2.2 dBi .Other antenna
arrangement is not covered by this certification.
The antennas are not field replaceable. If the antennas need to be changed, the certification
should be re-applied.
2.4 Limited module procedures
This module can be used in lighting equipment, smart front panel, household electrical
appliances. Normally host device should provide a power supply in range 4.5~5.5V, typically
5.0V for this module. The limited module manufacturer will review detailed test data or host
designs prior to giving the host manufacturer approval.
2.5 Trace antenna designs Not applicable
2.6 RF exposure considerations
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with minimum distance 20cm
between the radiator& your body. If the device built into a host as a portable usage, the
additional RF exposure evaluation may be required as specified by§ 2.1093.
2.7 Antennas
Module only contains one SMD chip antenna and one u.fl connector for the installation of an
external antenna.
2.8 Label and compliance information
The outside of final products that contains this module device must display a label referring
to the enclosed module. This exterior label can use wording such as: “Contains Transmitter
Module FCC ID: 2AT9I–PYBD”, or “Contains FCC ID: 2AT9I–PYBD”, Any similar wording
that expresses the same meaning may be used.