2.9 Information on test modes and additional testing requirements
a) The modular transmitter has been fully tested by the module grantee on the required
number of channels, modulation types, and modes, it should not be necessary for the host
installer to re-test all the available transmitter modes or settings. It is recommended that the
host product manufacturer, installing the modular transmitter, perform some investigative
measurements to confirm that the resulting composite system does not exceed the spurious
emissions limits or band edge limits (e.g., where a different antenna may be causing
additional emissions).
b) The testing should check for emissions that may occur due to the intermixing of emissions
with the other transmitters, digital circuitry, or due to physical properties of the host product
(enclosure). This investigation is especially important when integrating multiple modular
transmitters where the certification is based on testing each of them in a stand-alone
configuration. It is important to note that host product manufacturers should not assume that
because the modular transmitter is certified that they do not have any responsibility for final
product compliance.
c) If the investigation indicates a compliance concern the host product manufacturer is
obligated to mitigate the issue. Host products using a modular transmitter are subject to all
the applicable individual technical rules as well as to the general conditions of operation in
Sections 15.5, 15.15, and 15.29 to not cause interference. The operator of the host product
will be obligated to stop operating the device until the interference has been corrected
Below are steps for TX verification:
wl4343WA1.exe --serial 99 down
wl4343WA1.exe --serial 99 country ALL
wl4343WA1.exe --serial 99 band b
wl4343WA1.exe --serial 99 chanspec -c 1 -b 2 -w 20 -s 0
wl4343WA1.exe --serial 99 mpc 0
wl4343WA1.exe --serial 99 ampdu 1
wl4343WA1.exe --serial 99 bi 65000
wl4343WA1.exe --serial 99 frameburst 1
wl4343WA1.exe --serial 99 rateset 11b
wl4343WA1.exe --serial 99 up
wl4343WA1.exe --serial 99 txant 0
wl4343WA1.exe --serial 99 antdiv 0
wl4343WA1.exe --serial 99 nrate -r 11
wl4343WA1.exe --serial 99 phy_watchdog 0
wl4343WA1.exe --serial 99 disassoc
wl4343WA1.exe --serial 99 txpwr1 -1
wl4343WA1.exe --serial 99 pkteng_start 00:90:4c:aa:bb:cc tx 40 1000 0
To stop transmitting:
wl4343WA1.exe --serial 99 pkteng_stop tx