Cut Sheet
WIRE DIAGRAM
120V
LIGHT
FIXTURE
OPEN LOOP
SWITCH
Red Wire
White Zip Wire
Black
Wire
Hot
Neutral
CC-01
CURRENT
CONTROLLER
GEORGE RISK INDUSTRIES, INC.
G.R.I. PLAZA
KIMBALL, NE 69145
MADE IN U.S.A.
TOLL-FREE 1-800-445-5218
TOLL-FREE 1-800-523-1227
(308) 235-4645
FAX (308) 235-3561
E-MAIL: grisales@megavision.com
WEB SITE: www.grisk.com
BA-169 Rev I 1/15/08
WARRANTY:
One year warranty against workmanship, material and factory defects
INSTALLATION:
A) Installing the Door Sensor
NOTE: Open Loop Switch Required (included). Install the switch on the door, according to the manufactur-
ers installation instructions. Run wires from the door switch to the electrical junction box.
B) Installing the GRI Current Controller
NOTE: The installation of the GRI Current Controller must be performed by a licensed Electrician.
CAUTION: Remove branch power before installing CC-01.
Run light fixture wires from the light fixture to the electrical junction box. Run electrical wires from branch
circuit to the electrical junction box. Connect the white zip wire from CC-01 to the door switch wires using
the supplied blue wire connectors. Connect the red wire from CC-01 to the hot wire of the light fixture. The
other light fixture wire is connected to neutral using the supplied wire connectors. Connect the black wire
from CC-01 to the electrical hot wire from the AC branch using the supplied yellow wire connectors. After all
the connections have been made, the CC-01 can be placed into the electrical junction box. Secure the box
lid and reapply power to the branch circuit.