Cut Sheet
GEORGE RISK INDUSTRIES, INC.
G.R.I. PLAZA
KIMBALL, NE 69145
MADE IN U.S.A.
TOLL-FREE 1-800-445-5218
TOLL-FREE 1-800-523-1227
(308) 235-4645
FAX (308) 235-3561
E-MAIL: grisales@megavision.com
WEB SITE: www.grisk.com
CURRENT
CONTROLLER
The GRI Current Controller is an encapsulated circuit with connecting wires to AC power, a light fixture
and door monitor switch. A microprocessor circuit is safely isolated from the 120 volts AC. This control
signal through the door switch will control the AC power to the light fixture. The GRI Current Controller is
designed to fit into an electrical junction box along with the connecting wires.
NOTE: Open Loop Switch required. GRI 60-12 included.
SPECIFICATIONS:
Maximum Input Voltage 125 VAC
Maximum Output Current 1 A
Maximum Output Power 125 VA
Recommended Output Load 60 VA
Door Switch Voltage 3 VDC
Door Switch Current 3 uA
CC-01
K U.L. & U.L.C. Listed K Designed For Lamp Switching
K Use For Walk-in Closets, Pantries, And Cabinets
K Automatic AC Voltage Switching System
K Monitors The State Of A Low Voltage Switch Connected To The Door
CC-01
1.85” x 1.25”
NEW
U
LISTEDLISTED
L
U
L
C
®