• By using multiple Data Management Panels, the NuScribe computer can upload or commission
many NRUs simultaneously.
• The Data Management ports are hard plastic cups with 2 springs that make contact with the
NRU power pins for turning on the NRU prior to offloading or commissioning and applying a
charge voltage during offload or commissioning.
• The cup connectors are numbered 1 to 8. Number 8 is always at the end of the panel that has
the ethernet ports and power connector.
• Each Data Management cup connector has a TransferJet antenna built into the base, which
communicates with the NRU for downloading and commissioning via a proximity EM field.
• The panel has 8 ethernet ports, corresponding to the 8 cup connectors of the panel.
Figure 23
• The 8 ethernet ports connect to an ethernet switch which is used to interconnect other Data
Management Panels and the NuScribe computer.
• The power connector is next to the ethernet ports. It is a 4-pin connector. Power input is 12vdc.
• The panels can be wall mounted, rack mounted, or portable case mounted. See the Portable
Case chapter for information on the Portable Data Management Case.
Data Management Panel Use
• To carry out NRU uploading or commissioning operations, the panel must be connected to a
NuScribe computer via the ethernet ports and switch.
• The NRUs should be clean prior to loading into the panel. Muddy or wet NRUs need to be
cleaned and allowed to dry.
• Once the NRUs are loaded into the Data Management ports, follow the NuScribe manual
directions for either upload or commissioning. See NuScribe manual Rack View section.
Figure 24