Specifications
NUSITE
NUSEIS
Geophysical Technology Inc NuSite Page | 31
Figure 31
▪ Last Scan Time – time of last scan in the NuSite database. Attention should be
paid to this field to see if the unit status is updating. If the Last Scan Time is not
updating, then no new scans are being received by the NuSite device.
▪ Unit Type – type of NRU recording unit
▪ RSSI – signal level of BLE if the NRU is broadcasting and in range of the NuSite
device.
▪ Job Identifier – job number and CRC of internal settings. This is used to ensure
that the NRU has been programmed with the correct settings for the current
project. If the job number and CRC read from the unit are different from what
was defined, this field will turn red and the Overview bar at the top will turn red
and show the number of error values detected in the Overview field.
• This field will only flag red if a Work Order has been synchronized to the
NuSite device from NuScribe.
• If no Work Order has been synchronized, the field will remain white and
not flag an incorrect Job Identifier as there is no cross check without a
Work Order.
▪ Battery Remaining – shows the percentage of battery life remaining.
▪ Memory Remaining – indicates the total percentage of internal memory left for
recording data.
o Deployment – tapping on the Deployment bar will open the deployment details field for
the NRU