Users Manual

NUSITE
NUSEIS
Geophysical Technology Inc NuSite Page | 38
o General this is the same as the Overview field in the NRU Details page.
o Battery and Charger this is an extended version of the Environment field from the NRU
Details page. This page is for engineering information and will be phased out in future
releases.
Figure 38
Engineering -Only Field: Raw Data (20 Bytes) currently present to be used for
Engineering purposes, not useful to the user.
Charger Status status of the charger circuit expressed in hexadecimal format.
Charger Fault Status should show 0x0 in hexadecimal format if no faults. If a fault
is occurring, that status would be shown in hexadecimal format and the line would
turn red.
Charger Enabled charger enabled status would be shown as either True or False.
State of Charge expressed in a percentage, with 100% indicating full charge of
battery.
Remaining Capacity value in milliamp hours, shows battery remaining capacity. If
the capacity is below a threshold set in the parameters, this line will be yellow as a
warning.
Voltage battery voltage shown in millivolts.
Average Current expressed in milliamps, average charge current for battery
charging.
Instantaneous Current expressed in milliamps, battery charging current at the
time of the scan from the NRU.
Internal Temperature internal temperature of the NRU listed in degrees Celsius.
Cycle Count not implemented.