o Tapping on the Environment Bar will drop down the Environment field details. These fields
will only be populated if the NRU is in a deployed state. Only Battery Voltage will be
populated if the NRU is in an Un-deployed state.
Figure 34
Spread Noise the amount of average noise detected on the geophone
element/string during geophone tests. If the noise level exceeds the threshold
set in the parameter setup, this field will turn red and the Environment Bar will
turn red and indicate the number of errors in the Environment field.
Battery Voltage indicates the voltage of the internal battery of the NRU. If the
Battery Voltage is below 3.6 volts, the Battery Voltage field will turn yellow as a
warning and the Environment Bar will turn yellow and indicate the number of
warnings in the Environment field.
Temperature gives the internal temperature of the NRU in degrees Celsius.
Tilt Angle indicates the angle of the NRU as measured by the onboard
accelerometer. The measurement is done at intervals and updated in the BLE
status broadcast.
>=165 degrees is good. 180 degrees indicates perfect straight up and
down measurement.
164-160 will show a warning and the Title Angle field will turn yellow as
a warning and the Environment Bar will turn yellow and indicate the
number of warnings in the Environment field.
< 160 will show an error, this field will turn red and the Environment Bar