LineTrac XT
LineTrac XT is a passive AC current detector available for
StructureScan Mini XT as an additional purchase.
You will need the handle removal tool (looks like a screwdriver)
which was included with your StructureScan Mini XT. Note that
the LineTrac module can only be used on the front of the Mini
XT.
1 Make sure that the StructureScan Mini XT is powered
off and that the battery has been removed.
2 Using the tool provided with the Mini XT, remove the black, protective plate located below the
laser aperture on the front of the Mini XT. This will expose the gold-colored contacts. Take care
not to lose the two screws which secure the plate.
3 Slide the small eye-hole on the top of the LineTrac
module over the front guide post.
4 Using the provided tool, tighten down the two screws.
This will secure the LineTrac module onto the Mini XT.
5 Power up the StructureScan Mini XT as normal and
follow the steps in Section 5 to configure the LineTrac in
the software.
ScanMax app setup screen. Not the lightening icon in the lower-left corner. This indicates that the LineTrac hardware is
attached and powered up.