User Manual
Table Of Contents
- Limited Warranty, Limitations Of Liability And Restrictions
- Garantie limitée, limites de responsabilité et restrictions
- FCC Notice (for U.S. Customers):
- (a) UWB imaging systems require coordination through the FCC before the equipment may be used. The operator shall comply with any constraints on equipment usage resulting from this coordination.
- Or
- Frequency Coordination Branch, OET
- ATTN: UWB Coordination
- Canadian Requirements for RSS-220
- Canadian Requirements of RSS-220 for Ground Antennas
- Canadian Requirements of RSS-220 for Hand-held Antennas
- Canadian Requirements of RSS-220 for Search and Rescue Antennas
- Table of Contents
- Section 1: Introduction 1
- StructureScan™ Mini XT 2
- Section 2: Getting Started 3
- Section 3: Using ScanEZ Mode 5
- Section 4: Using the Scan3D App 10
- Section 5: Using the ScanMax App 14
- Section 6: Calibrating for Depth in the ScanMax App 20
- Section 7: Using the DualScan App 23
- Section 8: File Management 26
- Setting up Your Laptop/PC and Data Transfer 27
- Launching and Navigating the Software 28
- Viewing and Processing the Data 30
- Processing the Data 32
- Ribbon Options 34
- Home Ribbon Options 34
- 3D Volume Options Ribbon 40
- Chapter 1: Using the StructureScan Mini XT
- Section 1: Introduction
- StructureScan™ Mini XT
- Section 2: Getting Started
- Section 3: Using ScanEZ Mode
- Section 4: Using the Scan3D App
- Section 5: Using the ScanMax App
- Section 6: Calibrating for Depth in the ScanMax App
- Section 7: Using the DualScan App
- Section 8: File Management
- Chapter 2: Using RADAN for StructureScan Mini
- Setting up Your Laptop/PC and Data Transfer
- Launching and Navigating the Software
- Viewing and Processing the Data
- Processing the Data
- Ribbon Options
- Home Ribbon Options
- 3D Volume Options Ribbon
- Appendix A: The Dielectric Constant
- Appendix B: Data Interpretation and Examples of Common Features
- Appendix C: Technical Specifications
- Appendix D: Accessories
- Appendix E: Labeling
Geophysical Survey Systems, Inc. StructureScan™ Mini XT
Manual
MN 70-813 Rev C 45
Empty PVC Conduit
The hyperbola identified by the orange arrow is an empty PVC conduit above a row of rebar. Note that
the dominate color for the PVC hyperbola is black while the rebar is white. The PVC wall is too thin for
GPR to image so we are reflecting off of the air void within the conduit. This produces a negative (black)
response since the energy is traveling from a higher dielectric (concrete) to a lower dielectric (air) in the
same manner as the void example earlier.
If the PVC conduit were filled with wire or liquid
the image would more closely resemble the rebar
image since there is now less air by volume in the
conduit.
GSSI recommends exercising extreme caution
when clearing out areas known or suspected to
contain conduits.