User Manual
Table Of Contents
- Limited Warranty, Limitations Of Liability And Restrictions
- Garantie limitée, limites de responsabilité et restrictions
- FCC Notice (for U.S. Customers):
- (a) UWB imaging systems require coordination through the FCC before the equipment may be used. The operator shall comply with any constraints on equipment usage resulting from this coordination.
- Or
- Frequency Coordination Branch, OET
- ATTN: UWB Coordination
- Canadian Requirements for RSS-220
- Canadian Requirements of RSS-220 for Ground Antennas
- Canadian Requirements of RSS-220 for Hand-held Antennas
- Canadian Requirements of RSS-220 for Search and Rescue Antennas
- Table of Contents
- Section 1: Introduction 1
- StructureScan™ Mini XT 2
- Section 2: Getting Started 3
- Section 3: Using ScanEZ Mode 5
- Section 4: Using the Scan3D App 10
- Section 5: Using the ScanMax App 14
- Section 6: Calibrating for Depth in the ScanMax App 20
- Section 7: Using the DualScan App 23
- Section 8: File Management 26
- Setting up Your Laptop/PC and Data Transfer 27
- Launching and Navigating the Software 28
- Viewing and Processing the Data 30
- Processing the Data 32
- Ribbon Options 34
- Home Ribbon Options 34
- 3D Volume Options Ribbon 40
- Chapter 1: Using the StructureScan Mini XT
- Section 1: Introduction
- StructureScan™ Mini XT
- Section 2: Getting Started
- Section 3: Using ScanEZ Mode
- Section 4: Using the Scan3D App
- Section 5: Using the ScanMax App
- Section 6: Calibrating for Depth in the ScanMax App
- Section 7: Using the DualScan App
- Section 8: File Management
- Chapter 2: Using RADAN for StructureScan Mini
- Setting up Your Laptop/PC and Data Transfer
- Launching and Navigating the Software
- Viewing and Processing the Data
- Processing the Data
- Ribbon Options
- Home Ribbon Options
- 3D Volume Options Ribbon
- Appendix A: The Dielectric Constant
- Appendix B: Data Interpretation and Examples of Common Features
- Appendix C: Technical Specifications
- Appendix D: Accessories
- Appendix E: Labeling
Geophysical Survey Systems, Inc. StructureScan™ Mini XT
Manual
MN 70-813 Rev C 43
Appendix B: Data Interpretation and Examples
of Common Features
This section presents some data images of some common targets. While the GPR cannot differentiate
different types of metal (rebar vs. metal conduit vs. post-tensioned cables) on the basis of the signal alone,
the depth, spacing, and direction of the object often gives us clues as to its identification.
Welded Wire Mesh
This image shows a section of 6” wire mesh. There are two main clues here:
1 The even spacing.
2 The change in depth.
Since mesh is produced in a factory to have a constant spacing (6” is typical) the spacing between the
hyperbolas which denote the wires will be constant. Mesh is installed in long rolls and tends to depress as
it is weighted down by heavy concrete during the pour. The result is often a wavy appearance.
Note the bright white dot shown by the orange arrow. This is caused by the energy reflecting off two
adjacent pieces of mesh. The reflections get added together and show as brighter than a single piece. This
is not an additional target.