User Manual
Table Of Contents
- Limited Warranty, Limitations Of Liability And Restrictions
- Garantie limitée, limites de responsabilité et restrictions
- FCC Notice (for U.S. Customers):
- (a) UWB imaging systems require coordination through the FCC before the equipment may be used. The operator shall comply with any constraints on equipment usage resulting from this coordination.
- Or
- Frequency Coordination Branch, OET
- ATTN: UWB Coordination
- Canadian Requirements for RSS-220
- Canadian Requirements of RSS-220 for Ground Antennas
- Canadian Requirements of RSS-220 for Hand-held Antennas
- Canadian Requirements of RSS-220 for Search and Rescue Antennas
- Table of Contents
- Section 1: Introduction 1
- StructureScan™ Mini XT 2
- Section 2: Getting Started 3
- Section 3: Using ScanEZ Mode 5
- Section 4: Using the Scan3D App 10
- Section 5: Using the ScanMax App 14
- Section 6: Calibrating for Depth in the ScanMax App 20
- Section 7: Using the DualScan App 23
- Section 8: File Management 26
- Setting up Your Laptop/PC and Data Transfer 27
- Launching and Navigating the Software 28
- Viewing and Processing the Data 30
- Processing the Data 32
- Ribbon Options 34
- Home Ribbon Options 34
- 3D Volume Options Ribbon 40
- Chapter 1: Using the StructureScan Mini XT
- Section 1: Introduction
- StructureScan™ Mini XT
- Section 2: Getting Started
- Section 3: Using ScanEZ Mode
- Section 4: Using the Scan3D App
- Section 5: Using the ScanMax App
- Section 6: Calibrating for Depth in the ScanMax App
- Section 7: Using the DualScan App
- Section 8: File Management
- Chapter 2: Using RADAN for StructureScan Mini
- Setting up Your Laptop/PC and Data Transfer
- Launching and Navigating the Software
- Viewing and Processing the Data
- Processing the Data
- Ribbon Options
- Home Ribbon Options
- 3D Volume Options Ribbon
- Appendix A: The Dielectric Constant
- Appendix B: Data Interpretation and Examples of Common Features
- Appendix C: Technical Specifications
- Appendix D: Accessories
- Appendix E: Labeling
Geophysical Survey Systems, Inc. StructureScan™ Mini XT
Manual
MN 70-813 Rev C 35
2 Click on Focus.
3 Adjust the slider bar to increase or decrease the velocity (thus increase or
decrease the dielectric) and click on the Test Icon.
4 Continue to make adjustments and press the Test Icon until the hyperbolas
become dots.
• The picture on the left has hyperbolas. Increase the velocity bar by sliding it to the right. This will
automatically decrease the dielectric.
• The picture in the middle has upside-down hyperbolas. Decrease the velocity by sliding it to the
left. This will automatically increase the dielectric.
• The picture on the right has no hyperbolas. Dots are present.
5 Click on the Process Icon to process the data.
6 Save the data if prompted to do so.
Background Removal
Remove any background noise your data may have. Clicking on this icon will