User Manual
Table Of Contents
- Limited Warranty, Limitations Of Liability And Restrictions
- Garantie limitée, limites de responsabilité et restrictions
- FCC Notice (for U.S. Customers):
- (a) UWB imaging systems require coordination through the FCC before the equipment may be used. The operator shall comply with any constraints on equipment usage resulting from this coordination.
- Or
- Frequency Coordination Branch, OET
- ATTN: UWB Coordination
- Canadian Requirements for RSS-220
- Canadian Requirements of RSS-220 for Ground Antennas
- Canadian Requirements of RSS-220 for Hand-held Antennas
- Canadian Requirements of RSS-220 for Search and Rescue Antennas
- Table of Contents
- Section 1: Introduction 1
- StructureScan™ Mini XT 2
- Section 2: Getting Started 3
- Section 3: Using ScanEZ Mode 5
- Section 4: Using the Scan3D App 10
- Section 5: Using the ScanMax App 14
- Section 6: Calibrating for Depth in the ScanMax App 20
- Section 7: Using the DualScan App 23
- Section 8: File Management 26
- Setting up Your Laptop/PC and Data Transfer 27
- Launching and Navigating the Software 28
- Viewing and Processing the Data 30
- Processing the Data 32
- Ribbon Options 34
- Home Ribbon Options 34
- 3D Volume Options Ribbon 40
- Chapter 1: Using the StructureScan Mini XT
- Section 1: Introduction
- StructureScan™ Mini XT
- Section 2: Getting Started
- Section 3: Using ScanEZ Mode
- Section 4: Using the Scan3D App
- Section 5: Using the ScanMax App
- Section 6: Calibrating for Depth in the ScanMax App
- Section 7: Using the DualScan App
- Section 8: File Management
- Chapter 2: Using RADAN for StructureScan Mini
- Setting up Your Laptop/PC and Data Transfer
- Launching and Navigating the Software
- Viewing and Processing the Data
- Processing the Data
- Ribbon Options
- Home Ribbon Options
- 3D Volume Options Ribbon
- Appendix A: The Dielectric Constant
- Appendix B: Data Interpretation and Examples of Common Features
- Appendix C: Technical Specifications
- Appendix D: Accessories
- Appendix E: Labeling
Geophysical Survey Systems, Inc. StructureScan™ Mini XT
Manual
MN 70-813 Rev C 30
Viewing and Processing the Data
Preparing the Software
Before opening a file, you will need to set up some Global
Settings located on the right side of the screen. If the Settings info
(at right) is not shown, click the Global Settings button from the
Other Windows section of the Home tab. Click on the following
to change the parameters:
Auto Save Files: Click here, then click on the down arrow to
select one of the following values:
• Yes: Automatically save a processed file. RADAN will
automatically create a folder called “Proc” inside your
source directory and save processed data there.
• No: You will be prompted to save a processed file.
Source Directory: Click here, then click on the three dots to
browse to the source folder where you copied your source
(original) data.
Output Directory: Click here, then click on the three dots to
browse to the output folder you created from your source folder.
You will not see this option if you have set your Auto Save File to
Yes.
Marker Style:
• Short: Display user marks extending down a short distance from the top of the scan.
• Long: Display user marks extending through entire scan.
• None: Hide all marks.
Horizontal Scale:
• Show: Display horizontal scale.
• Hide: Do not display horizontal scale.
Grid Lines:
• Show: Display grid lines.
• Hide: Do not display grid lines.
Vertical Units: Units for the vertical scale.
Horizontal Units: Units for the horizontal scale.
GPS Units: Different options to display GPS information, if it is available: (1) decimal degrees; (2)
degrees, minutes, seconds; (3) decimal degrees and minutes; and (4) UTM.
Auto-Switch Display:
• Yes: The display will change based on the data file opened.
• No: Data will open in the currently selected display.
Note: Once you open a file, you
cannot change any of the
Global Settings. You must close all
files to make changes.