User Manual
Table Of Contents
- Limited Warranty, Limitations Of Liability And Restrictions
- Garantie limitée, limites de responsabilité et restrictions
- FCC Notice (for U.S. Customers):
- (a) UWB imaging systems require coordination through the FCC before the equipment may be used. The operator shall comply with any constraints on equipment usage resulting from this coordination.
- Or
- Frequency Coordination Branch, OET
- ATTN: UWB Coordination
- Canadian Requirements for RSS-220
- Canadian Requirements of RSS-220 for Ground Antennas
- Canadian Requirements of RSS-220 for Hand-held Antennas
- Canadian Requirements of RSS-220 for Search and Rescue Antennas
- Table of Contents
- Section 1: Introduction 1
- StructureScan™ Mini XT 2
- Section 2: Getting Started 3
- Section 3: Using ScanEZ Mode 5
- Section 4: Using the Scan3D App 10
- Section 5: Using the ScanMax App 14
- Section 6: Calibrating for Depth in the ScanMax App 20
- Section 7: Using the DualScan App 23
- Section 8: File Management 26
- Setting up Your Laptop/PC and Data Transfer 27
- Launching and Navigating the Software 28
- Viewing and Processing the Data 30
- Processing the Data 32
- Ribbon Options 34
- Home Ribbon Options 34
- 3D Volume Options Ribbon 40
- Chapter 1: Using the StructureScan Mini XT
- Section 1: Introduction
- StructureScan™ Mini XT
- Section 2: Getting Started
- Section 3: Using ScanEZ Mode
- Section 4: Using the Scan3D App
- Section 5: Using the ScanMax App
- Section 6: Calibrating for Depth in the ScanMax App
- Section 7: Using the DualScan App
- Section 8: File Management
- Chapter 2: Using RADAN for StructureScan Mini
- Setting up Your Laptop/PC and Data Transfer
- Launching and Navigating the Software
- Viewing and Processing the Data
- Processing the Data
- Ribbon Options
- Home Ribbon Options
- 3D Volume Options Ribbon
- Appendix A: The Dielectric Constant
- Appendix B: Data Interpretation and Examples of Common Features
- Appendix C: Technical Specifications
- Appendix D: Accessories
- Appendix E: Labeling
Geophysical Survey Systems, Inc. StructureScan™ Mini XT
Manual
MN 70-813 Rev C 24
Collecting Data
If you already have a Base file,
1 Click Files to display the file selection
screen. You will see the image at the
right.
2 Choose the desired base file and click Set
as Base. A green check will appear next
to the file entry.
3 Click Scan Setup to return to the Scan
Setup screen. You will see the name of
the selected file displayed near the top-
left as Base: FILENAME.
4 Click Scan to begin collecting data. The
Base file will be displayed on the bottom. The XT will continue to collect data to the Comparison file
even if it is longer than the Base file, but the XT will write zero amplitude dummy data on the screen
to the Base file for any scans in excess of the Base file.
If you do not have a saved Base file,
1 Click Scan from the Scan Setup screen and collect a file. GSSI suggests marking the location of the
side lasers on the concrete so that you can line up successive comparison files. This first file will be
your base file. Click Close File when you have finished your Base file. You will be returned to the
Scan Setup screen.
2 Position the XT at the location of your comparison line and click Scan to begin collecting data. The
Base file will be displayed on the bottom. The XT will continue to collect data to the Comparison file
even if it is longer than the Base file, but the XT will write zero amplitude dummy data on the screen
to the Base file for any scans in excess of the Base file.
3 Successive comparison files will all use the original Base file.
Project 1, Comparison
File 002, Base File 001
Comparison File
Base File