User's Manual

Quick Start Guide UtilityScan 350HS
Copyright © 2012 Geophysical Survey Systems, Inc. 21
All Rights Reserved
Gain Settings
Gain Mode
Auto allows the system to configure the Gain.
Manual allows the user to configure the Gain.
Number of Points (Only if Gain Mode is set to Manual) Number of
points or “Individual Sections” to adjust the Gain.
Ranges for 1 point to 8 points.
GP1: 8 (Only if Gain Mode is set to Manual)
Depending upon number of Gain Points, adjust each section accordingly.
Values range from -42 to 126.
Note: Tap on the double arrows (up or down) to display the appropriate gain points.
Filters (See Appendix E for more information)
Stacking: To reduce random or high frequency noise in your data.
Background Removal: Remove horizontal banding in your data.
Noise Indicator
On: Display approximately the depth where data becomes too weak.