User's Manual
Table Of Contents
- Limited Warranty, Limitations Of Liability And Restrictions
- FCC Notice (for U.S. Customers):
- Coordination Requirements
- Cet appareil de radar au travers des murs ne doit être utilisé que par les forces de l’ordre ou les organisations de secours d’urgence ou de combat du feu qui sont sous une autorité locale, provinciale ou fédérale. Cet équipement ne doit être utilisé que dans le cadre de services et pour les opérations d’entrainement nécessaires. Certificate
- Ground Penetrating Radar Coordination Notice And
- Equipment Registration
- And
- System Setup - Standard Settings
- Using Your 3101A Antenna with a Survey Wheel
- Antenna Specifications
Geophysical Survey Systems, Inc. Model 3101A Series Antennas
System Settings and User Notes
Model 3101A Antenna
Thank you for purchasing a GSSI 3101A. The Model 3101A antenna is a high frequency antenna
that is designed for applications requiring very fine resolution and shallow depth penetration in a
variety of materials. Please take a moment to examine your shipment to familiarize yourself with
this manual. If you need assistance, GSSI technical support can be reached Monday-Friday, 8am-
5pm, US Eastern Time at (800) 524-3011, or at (603) 893-1109 (International). You can also
access technical support on the web at www.geophysical.com.
The Model 3101A can be used in continuous, survey wheel or static stacking modes. Please
consult your control unit documentation for instructions on configuring your system for data
collection modes.
System Setup - Standard Settings
Preset Settings:
System Run Mode: Survey Wheel (recommended) or Continuous
Range: 15 ns
Number of Gain Points: 3
Vertical Low Pass Filter: 2500 MHz
Vertical High Pass Filter: 225 MHz
Samples per Scan: 512
Bits per Sample: 16
Scans per Second: Set to 64 (increase to 120 when using survey wheel).
Deeper Profiling:
Setup Mode: Manual
System Run Mode: Survey Wheel (recommended) or Continuous
Range: 30 – 50 ns
Number of Gain Points: 3
Vertical Low Pass Filter: 2500 MHz
Vertical High Pass Filter: 225 MHz
Samples per Scan: 512
Bits per Sample: 16
Scans per Second: to 64 (increase to 120 when using survey wheel).