User Manual
Total Station Manual
208
10. Technical parameters
Function Unit
Configuration
ZOOM 10
Telescope
Imaging — Erect
Magnification × 30
Field of view — 1
ώ
20′
Min.target distance m 1.5
Effective aperture mm 40/50(EDM)
Angle
measurement
(Hz, V)
2C index error (″) 1.4
Angle i index error (″)
2.0
Angle measurement method — Absolute encoder
Minimum reading (″)
1
Distance
measurement (IR)
Range
Single prism km 3
Triple prism km
5
No- prism1 m 400
Time
Repeated s
2(first 3)
Tracking s 0.8
Minimum display mm 0.1
Accuracy
Prism
mm
±(2
ˇ
2×10
-6
D)
No- prism ±(3
ˇ
2×10
-6
D)
Tilt compensator
Compensation method — Biaxial type
Compensation range
˄
′
˅
±3
Communication Port — RS232C
U disk interface — Yes
Bluetooth — Yes
Temperature and pressure sensor — No
SD card — Yes