User Manual

Total Station Manual
194
value,press
[F4](OK) ,and then turn
90 ° clockwise back to
the original direction.
ƻ
2 Use fine tuning to set
the vertical angle to
V0-3’, focus on the
reticle center accurately,
then turn the instrument
counterclockwise 90 °,
wait for stable value,
press [F4] (OK) ,and
then turn 90 ° clockwise
back to the original
direction.
[F4]
ƻ
3 Use fine tuning to set
the vertical angle as
V0,focus on the reticle
center accurately.
ƻ
4Reversethe
telescope, use face right
to focus on the reticle of
collimator,record the
vertical angle V1.Use
fine tuning to set the
vertical angle as
V1-3’,focus on the
reticle center accurately,
then turn the instrument
counterclockwise 90 °,
wait for stable value,
pressF4(OK) ,and then
turn 90 ° clockwise back
to the original direction.
[F4]