User Manual
Total Station Manual
44
between cylinder and station.
Steps Key Display
ƻ
1 In the program of
Q-Survey, press [FNC] to
enter the menu of Function,
then pressing [F2] to enter
the program of Offset.
[F2]
ƻ
2
Press [F2] to enter the
subprogram of Cylinder
Offset.
[F2]
ƻ
3
Aim at the left edge of
cylinder, press [F1] to make
suretheangelofHzLeft,
turn the instrument to aim at
the right edge of cylinder and
press [F2] to make sure the
angle of Hz Right.
[F1]+[F2
]
ƻ
4 Turn the instrument to
make
Ƹ
Hz=0, if use the
prism,please input the
thickness of prism in the edit
text of PrismOFS, if don’t
use the prism, the default
value is 0 in the edit of
PrismOFS, then press [F3] to
measure the shortest distance
of the instrument to cylinder
and enter the interface of
Cylinder Offset-Result.
[F3]
or
[F4] +
[F1]+[F2
]