User Manual
Total Station Manual
26
2. EDM Setting
2.1 Set the mode of EDM
Select the mode of distance measurement,there are 6 modes :
Single,Repeat,Tracking,3 Times,4 Times,5 Times.
Steps Key Display
ƻ
1
Press [F4](
Ę
)and show
the second soft key in the
Q-Surveying. Press [F3] to
enter the interface of EDM
Setting.
[F4]
[F3]
ƻ
2
When the cursor is in
EDM mode option,Press the
direction key of
ĕė
to select
the mode of
measurement.Each time you
press
ĕ
or
ė
, the mode of
measurement is switched.
ĕ
ė
ƻ
3 After finishing setting,
press [F3](OK) to return the
function of Q-Surveying.If
you want to cancel the
settings, press [ESC] to ignore
the changes.
[F3]
Set the reflector type
Our series total station can be set up for the red laser (RL) range and invisible
infrared light (IR) range and the total station has three reflectors to be selected, which
are prism, non-prism (NP) and reflect board (Sheet). You can set by job,but the prism
used should be matched with prism constants.
¾ About the parameters of various reflectors in distance measurement, please