9.3 Distance Measurements without Reflectors (Reflectorless mode)
N5 (without reflector)
Kodak Gray Card Range D Range E Range F
[m] [ft] [m] [ft] [m] [ft]
White side, 90 % reflective 250 820 400 1312 >500 >1640
Grey side, 18 % reflective 100 330 150 490 >250 >820
Range Description
D Object in strong sunlight, severe heat shimmer
E Object in shade, or overcast
F Underground, night and twilight
Standard
measuring
ISO 17123-4 Measure time,
typical [s]
Measure time,
maximum [s]
0 m - 500 m 2 mm + 2 ppm 3 - 6 15
>500 m 4 mm + 2 ppm 3 - 6 15
Beam interruptions, severe heat shimmer and moving objects within the beam path can result in
deviations of the specified accuracy.
Continuous measuring* Standard deviation Measure time, typical [s]
Continuous 5 mm + 3 ppm 1.0
* Accuracy and measure time depend on atmospheric conditions, target object and observation
situation.
Type Description
Type Coaxial, visible red laser
Carrier wave 658 nm
Measuring system System Analyzer Basis 320 MHz
Distance [m] Laser dot size, approximately [mm]
at 50 12 x 24
9.4 Conformity to National Regulations
9.4.1 Zoom40
FCC Part 15, 22 and 24 (applicable in US)
Range
Atmospheric conditions
Accuracy
Characteristics
Laser dot size
Conformity to national
regulations
48 Technical Data