Product Manual

Table Of Contents
9 Technical Data
9.1 Angle Measurement
Accuracy Standard devi-
ation HA, VA,
ISO17123-3
Display resolution
["] [mgon] ["] [°] [mgon] [mil]
1 0.3 1 0.0001 0.1 0.01
2 0.6 1 0.0001 0.1 0.01
5 1.5 1 0.0001 0.1 0.01
Absolute, continuous, diametric.
9.2 Distance Measurement with Reflectors
Reflector Range A Range B Range C
[m] [ft] [m] [ft] [m] [ft]
Standard prism 1800 6000 3000 10000 3500 12000
Reflector foil
60 mm x 60 mm
150 500 250 800 250 800
Shortest measuring distance: 1.5 m
Range Description
A Strong haze, visibility 5km; or strong sunlight, severe heat shim-
mer
B Light haze, visibility about 20km; or moderate sunlight, slight heat
shimmer
C Overcast, no haze, visibility about 40km; no heat shimmer
Accuracy refers to measurements to standard reflectors.
EDM measuring mode Standard deviation Measurement time, typical
[s]
IR-Standard 2 mm + 2 ppm 2.4
IR-Quick 3 mm + 2 ppm 2.0
IR-Continuous 3 mm + 2 ppm 0.33
Foil 5 mm + 2 ppm 2.4
Beam interruptions, severe heat shimmer and moving objects within the beam path can result in
deviations of the specified accuracy.
Absolute, continuous, diametric.
Accuracy
Characteristics
Range
Atmospheric conditions
Accuracy
Characteristics
Technical Data 47