5 Settings
5.1 General Settings
1. Select Settings from the MAIN MENU.
2. Select General from the SETTINGS menu.
Field Description
Tilt Corr. OFF Tilting compensation deactivated.
ON Two-axis compensation. Vertical angles refer to the
plummet line and the horizontal directions are correc-
ted by the standing axis tilt.
For corrections depending on the H.A. Corr. setting,
refer to the table "Tilt and horizontal corrections".
☞
If the instrument is used on an unstable base, for example a shaking plat-
form or ship, the compensator should be deactivated. The deactivation
avoids the compensator drifting out of its measuring range and interrupt-
ing the measuring process by indicating an error.
H.A. Corr. ON Horizontal corrections are activated. For normal opera-
tion, the horizontal correction should remain active.
Each measured horizontal angle is corrected, depend-
ing on the vertical angle.
For corrections depending on the Tilt Corr. setting,
refer to the table Tilt and horizontal corrections
.
Setting Correction
Tilt cor-
rection
Horizon-
tal cor-
rection
Incline
longitudi-
nal
Incline
trans-
versal
Horizontal collimation Tilting
axis
Off On No No Yes Yes
On On Yes Yes Yes Yes
Off Off No No No No
On Off Yes No No No
5.2 Regional Settings
1. Select Settings from the MAIN MENU.
2. Select Regional from the SETTINGS menu.
Field Description
H.A. Incr. Right Set horizontal angle to clockwise direction measure-
ment.
Left Set horizontal angle to counter-clockwise direction
measurement. Counter-clockwise directions are dis-
played but are saved as clockwise directions.
V.A. Setting Sets the vertical angle.
Access
General settings
Tilt and horizontal correc-
tions
Access
Regional settings
Settings 31