80EZiSYSTEM, Technical Data
10 Technical Data
10.1 Locator i-Series Technical Data
Typical detection range
Operating depth range
Typical depth accuracy
Mode Distance along conductor
Power mode length of conductor
Radio mode length of conductor
Conductive Rod mode length of unwound rod
Mode Range
Power mode to 3 m / 10 ft
Radio mode to 2 m / 7 ft
Transmitter mode Dependent on Transmitter and service type
EZiCAT i550, i650, i750 EZiCAT i550xf, i650xf, i750xf
10% of depth in line or Sonde 10% of depth in line or Sonde
0.3 to 3.0 m (1 to 10 ft) Line Mode
0.3 to 3.0 m (1 to 10 ft) Sonde Mode
0.3 to 3.0 m (1 to 10 ft) Line Mode
0.3 to 9.99 m (1 to 32 ft 9 inches) Sonde
Mode