Technical Data
I
12. Technical Data
Height measurements Standard deviation per km double run (ISO 17123-2):
Electronic measurement with ZDL700 barcode staff: 0.7 mm
Optical measurement with standard aluminum E-scale/Numeral staff: 2.5 mm
Distance Accuracy
(Standard Deviation)
10 mm for D<= 10 m
Distance in m x 0.001 for D>10 m
Range Distance measuring range for electronic measurements with barcode staff: 2 m to 105 m.
Optical - Shortest focusing
distance
50 cm
Measuring time single
measure (Electronic)
Typically 3 seconds and less in normal daylight condition; needs longer measuring time in uniform dim
light condition (20 lux).
Circular Bubble Circular Bubble Sensitivity: 10'/2 mm
Compensator Magnet damped pendulum compensator with electronic range monitoring
Tilt Warning Range (Electronically): ± 10'
Compensator range (Mechanically): ± 10'
Setting accuracy: 0.35" max. (Standard Deviation)
Magnetic field sensitivity: < 10"
(Line-of-sight difference in horizontal constant magnetic field at a field strength of up 5 Gauss)
RS232 Port For communication to PC / data collector via RS232 data transfer cable.
Internal Memory Storage Capacity: up to 2000 points.
Data Transfer Programs To PC via RS232 using GeoMax PC-Tools and HyperTerminal via RS232 on PC, using a Windows®
application
Battery Power AA dry cells 4 x 1.5 V