Product Manual
Table Of Contents
- 1 Safety Directions
- 2 Description of the System
- 3 User Interface
- 4 Operation
- 4.1 Main Menu
- 4.2 System Information
- 4.3 Setting Up the TPS Instrument
- 4.4 Setting up for Remote Control (with the RadioHandle)
- 4.5 Connecting to a Personal Computer
- 4.6 Power Functions
- 4.7 Batteries
- 4.8 Working with the Memory Device
- 4.9 Working with Bluetooth
- 4.10 LED Indicators
- 4.11 Guidelines for Correct Results
- 5 Settings
- 6 Apps
- 7 Care and Transport
- 8 Technical Data
- 8.1 Angle Measurement
- 8.2 Distance Measurement with Reflectors
- 8.3 Distance Measurement without Reflectors
- 8.4 Distance Measurement - Long Range (LO mode)
- 8.5 Automatic Prism Aiming AiM
- 8.6 Prism Search (Scout) - only available at Zoom90
- 8.7 Conformity to National Regulations
- 8.8 General Technical Data of the Product
- 8.9 Scale Correction
- 8.10 Reduction Formulas
- 9 Software Licence Agreement
- 10 Glossary
- Appendix A Menu Tree
- Appendix B Directory Structure
- Appendix C Pin Assignments
8 Technical Data
8.1 Angle Measurement
Available angular
accuracies
Standard deviation Hz, V,
ISO 17123-3
Display resolution
["] [mgon] ["]
1 0.3 0.1
2 0.6 0.1
5 1.5 0.1
Absolute, continuous, diametric.
8.2 Distance Measurement with Reflectors
Reflector Range A Range B Range C
[m] [ft] [m] [ft] [m] [ft]
Standard prism (ZPR100) 1800 6000 3000 10000 3500 12000
Three standard prisms
(ZPR100)
2300 7500 4500 14700 5400 17700
360° prism (ZPR1, GRZ122) 800 2600 1500 5000 2000 7000
Mini prism (ZMP100) 800 2600 1200 4000 2000 7000
Mini prism (ZMP101) 800 2600 1200 4000 2000 7000
Reflector tape (ZTM100)
60 mm x 60 mm
150 500 250 800 250 800
Shortest measuring distance: 1.5 m
Range Description
A Strong haze, visibility 5km; or strong sunlight, severe heat shim-
mer
B Light haze, visibility about 20km; or moderate sunlight, slight heat
shimmer
C Overcast, no haze, visibility about 40km; no heat shimmer
Measurements can be made to reflector tapes over the entire range without external ancillary
optics.
Accuracy refers to measurements to standard prisms.
EDM measuring
mode
std. dev.
ISO 17123-4,
standard prism
std. dev.
ISO 17123-4,
tape
Measurement time,
typical [s]
Standard 1 mm + 1.5 ppm 3 mm + 2 ppm 2.4
Single(fast) 2 mm + 1.5 ppm 3 mm + 2 ppm 0.8
Continuous 3 mm + 1.5 ppm 3 mm + 2 ppm < 0.15
Beam interruptions, severe heat shimmer and moving objects within the beam path can result in
deviations of the specified accuracy.
Accuracy
Characteristics
Range
Atmospheric conditions
☞
Accuracy
52 Technical Data