Product Manual
Table Of Contents
- 1 Safety Directions
- 2 Description of the System
- 3 User Interface
- 4 Operation
- 4.1 Main Menu
- 4.2 System Information
- 4.3 Setting Up the TPS Instrument
- 4.4 Setting up for Remote Control (with the RadioHandle)
- 4.5 Connecting to a Personal Computer
- 4.6 Power Functions
- 4.7 Batteries
- 4.8 Working with the Memory Device
- 4.9 Working with Bluetooth
- 4.10 LED Indicators
- 4.11 Guidelines for Correct Results
- 5 Settings
- 6 Apps
- 7 Care and Transport
- 8 Technical Data
- 8.1 Angle Measurement
- 8.2 Distance Measurement with Reflectors
- 8.3 Distance Measurement without Reflectors
- 8.4 Distance Measurement - Long Range (LO mode)
- 8.5 Automatic Prism Aiming AiM
- 8.6 Prism Search (Scout) - only available at Zoom90
- 8.7 Conformity to National Regulations
- 8.8 General Technical Data of the Product
- 8.9 Scale Correction
- 8.10 Reduction Formulas
- 9 Software Licence Agreement
- 10 Glossary
- Appendix A Menu Tree
- Appendix B Directory Structure
- Appendix C Pin Assignments
5.4 Atmospheric Settings
1. Select Settings from the MAIN MENU.
2. Select Atmos. from the SETTINGS menu.
DEFAULT To set all values to factory
default.
Field Description
Z(MSL) Sets the elevation above mean sea level.
Temperature Sets the temperature.
Pressure Sets the pressure.
Humidity Sets the humidity.
Atmos PPM The atmospheric ppm is calculated from the values in the previ-
ous fields.
Refr. Coeff Refraction coefficient to be used for calculation.
Use Refr.C. If YES, refraction correction is applied to measurements.
Access
ATMOSPHERIC SETTINGS
Settings 43