Product Manual

2. Take an elevation reading at Point A using the receiver and a survey rod.
3. Enter +5.000% grade into the X-axis. When grade is entered into the X-axis, the Y-
axis acts like a hinge or fulcrum.
4. With +5.000% in the X-axis, take a second reading at Point A.
5. Alignment:
If the second reading is equal to the first reading, the X-axis is aligned cor-
rectly.
If the second reading is greater than the first reading, rotate the Zone80 DG
clockwise (to the right) until the two readings are equal.
If the second reading is less than the first reading, rotate the Zone80 DG coun-
ter-clockwise (to the left) until the two readings are equal.
An optional sighting scope is available for the Zone80 DG which improves the axis
alignment for second day setups. It is recommended that you first perform the pre-
cise alignment procedure, and then adjust the scope to these axes.
3.9 Laydown Operation
You can use the Zone80 DG in laying down position to create a vertical plane for layout and
alignment jobs.
007597_001
Zone80 DG Laying down screen
Vertical plane of laser
light
22 Operation