Product Manual
Table Of Contents
- 1 Safety Directions
- 2 Description of the System
- 3 User Interface
- 4 Operation
- 5 Settings
- 6 Tools
- 7 Functions
- 8 Coding
- 9 MapView Interactive Display Feature
- 10 Applications - Getting Started
- 11 Applications
- 12 Data Management
- 13 Calibration
- 14 Care and Transport
- 15 Technical Data
- 15.1 Angle Measurement
- 15.2 Distance Measurement with Reflectors
- 15.3 Distancer, Measurements without Reflectors (Reflectorless mode)
- 15.4 Distance Measurement Reflector (Long Range)
- 15.5 Conformity to National Regulations
- 15.6 General Technical Data of the Product
- 15.7 Scale Correction
- 15.8 Reduction Formulas
- 16 Software Licence Agreement
- 17 Glossary
- Appendix A Menu Tree
- Appendix B Directory Structure
- Appendix C Connector PIN Layout
Field Description
Segm Segment number. Includes the misclosure segment, if applicable.
CumL Cumulation of the segment lengths. Changes with the current
number of segments. Includes the misclosure segment length if
applicable.
dH.A. Horizontal direction from the measured point to the setout point.
Positive if the telescope must be turned clockwise to the setout
point.
d.H.D. Horizontal distance from the measured point to the setout point.
Positive if the setout point is further away than the measured
point.
d.d.z. Height difference from the measured point to the setout point.
Positive if the setout point is higher than the measured point.
dL Longitudinal distance from the measured point to the setout
point. Positive if setout point is further away than the measured
point.
dO Perpendicular distance from the measured point to the setout
point. Positive if setout point is to the right of the measured
point.
The following are important messages or warnings that may appear.
Messages Description
Baseline too short! Base line is shorter than 1 cm. Choose base points
such that the horizontal separation of both points is
at least 1 cm.
Coordinates invalid! No coordinates or invalid coordinates for a point.
Ensure that points used have at least Easting and
Northing coordinates.
Recording to interface! Data Output is set to Interface in the GENERAL
SETTINGS menu. To be able to successfully start
reference line, Data Output must be set to Int.
Memory.
•
Either, press ALL to measure and record.
•
Or, press ESC to return to the Define Line Segment screen and from there, press BACK
to return to REFERENCE LINE screen.
•
Or, continue selecting ESC to exit the application.
11.10 Reference Element - Reference Arc
11.10.1 Overview
The Reference Element - Arc application allows the user to define a reference arc and then com-
plete the following tasks with respect to the arc:
•
Line & offset
•
Set out (Point, Arc, Chord, Angle)
1. Select Apps from the MAIN MENU.
2. Select R_ARC from the Apps menu.
3. Complete application pre-settings. Refer to "5 Applications - Getting Started".
Define the reference arc.
Messages
Next step
Description
Access
Next step
Applications 85