Product Manual

Table Of Contents
Field Description
Pt. Defined point ID of the centre point.
E Easting coordinate of the centre point.
N Northing coordinate of the centre point.
Z Height of the point measured with the reflector.
This is not the calculated height of the centre point.
Radius Radius of the cylinder.
7.4 2 Dist. Offset
This function is used for measurements to a point that is not directly visible, using a special 2
Dist. Offset pole.
1
2
3
1 E, N, Z of target point
2 Pole length
3 Distance P1-P2
1. Press FNC when within any application.
2. Select 2 Dist. Offset from the FUNCTIONS menu.
Next step
If required, press POLE to define the pole or EDM settings.
Field Description
Mode Changes the EDM Mode.
Type Changes the prism type.
GeoMax Const Displays the prism constant.
Pole Length Total length of 2 Dist. Offset pole
Dist. P1-P2 Spacing between the centers of the prisms P1 and P2.
Meas. Tol Limit for the difference between the given and measured
spacing of the prisms. If the tolerance value is exceeded,
the function will issue a warning.
Next step
In the 2 DIST. OFFSET screen, measure to the first and second prisms using ALL and the 2
DIST. OFFSET RESULT screen is displayed.
Displays Easting, Northing and Height coordinates of the target point.
Description
Access
POLE SETTINGS
2 DIST. OFFSET RESULT
50 Functions