Product Manual

Table Of Contents
Field Description
Off Bluetooth sensor is deactivated.
The following fields are active only when Port: RS232 is set.
Field Description
Baud rate Speed of data transfer from receiver to device in bits per second.
1200, 2400, 4800, 9600, 14400, 19200, 38400, 57600, 115200
Data bits Number of bits in a block of digital data.
7 Data transfer is realised with 7 databits.
8 Data transfer is realised with 8 databits.
Parity Even Even parity. Available if data bit is set to 7.
Odd Odd parity. Available if data bit is set to 7.
None No parity. Available if data bit is set to 8.
Endmark CR/LF The terminator is a carriage return followed
by a line feed.
CR The terminator is a carriage return.
Stop bits 1 Number of bits at the end of a block of digital
data.
Acknowledge On Acknowledgement expected from other
device after data transfer received. An error
message will display if no acknowledgement
is returned.
Off No acknowledgement expected after data
transfer.
5.4 Unit Settings
1. Select Settings from the MAIN MENU.
2. Select Unit from the Settings menu.
Field Description
Angle Unit Sets the units shown for all angular fields.
° ' " Degree sexagesimal.
Possible angle values: 0° to 359°59'59''
dec. deg Degree decimal.
Possible angle values: 0° to 359.999°
gon Gon. Possible angle values: 0 gon to 399.999 gon
mil Mil. Possible angle values: 0 to 6399.99mil.
The setting of the angle units can be changed at any time. The actual dis-
played values are converted according to the selected unit.
Min. Reading Sets the number of decimal places shown for all angular fields. This is for
data display and does not apply to data export or storage.
For Angle Unit ° ' '': (0° 00' 01" /0° 00' 05"/0° 00' 10").
Dec.deg: (0.0001 / 0.0005 / 0.001).
Gon: (0.0001 / 0.0005 / 0.001).
Mil: (0.01 / 0.05 / 0.1).
Dist. Unit Sets the units shown for all distance and coordinate related fields.
meter Meters [m].
ft (US) US feet [ft].
Access
Unit Settings
Applications - Getting Started 41