Product Manual

Table Of Contents
Field Description
On Visible laser beam for visualising the target point
is activated.
This screen enables the entry of atmospheric parameters. Distance measurement is influenced
directly by the atmospheric conditions of the air in which the measurements are taken. In order
to take these influences into consideration distance measurements are corrected using atmos-
pheric correction parameters.
The refraction correction is taken into account in the calculation of the height differences and the
horizontal distance. Refer to "15.7 Scale Correction" for the application of the values entered in
this screen.
When PPM=0 is selected, the GeoMax standard atmosphere of 1013.25 mbar,
12°C, and 60% relative humidity will be applied.
This screen enables entry of the scale of projection. Coordinates are corrected with the PPM
parameter. Refer to "15.7 Scale Correction" for the application of the values entered in this
screen.
This screen enables the entry of individual scaling factors. Coordinates and distance measure-
ments are corrected with the PPM parameter. Refer to "15.7 Scale Correction" for the application
of the values entered in this screen.
5.3 Communication Settings
For data transfer the communication parameters of the instrument must be set.
1. Select Settings from the MAIN MENU.
2. Select Comm. from the Settings menu.
BTCode
To set a code for the Bluetooth connection.
The default Bluetooth code is ’0000’.
Field Description
Port Instrument port.
RS232 Communication is via the serial interface.
USB Communication is via the USB host port.
Bluetooth Communication is via Bluetooth.
Bluetooth On Bluetooth sensor is activated.
ATMOSPHERIC DATA
ENTRY
PROJECTION SCALE
Free-PPM Entry
Description
Access
COMMUNICATION SET-
TINGS