Product Manual
Table Of Contents
- 1 Safety Directions
- 2 Description of the System
- 3 User Interface
- 4 Operation
- 5 Settings
- 6 Tools
- 7 Functions
- 8 Coding
- 9 MapView Interactive Display Feature
- 10 Applications - Getting Started
- 11 Applications
- 12 Data Management
- 13 Calibration
- 14 Care and Transport
- 15 Technical Data
- 15.1 Angle Measurement
- 15.2 Distance Measurement with Reflectors
- 15.3 Distancer, Measurements without Reflectors (Reflectorless mode)
- 15.4 Distance Measurement Reflector (Long Range)
- 15.5 Conformity to National Regulations
- 15.6 General Technical Data of the Product
- 15.7 Scale Correction
- 15.8 Reduction Formulas
- 16 Software Licence Agreement
- 17 Glossary
- Appendix A Menu Tree
- Appendix B Directory Structure
- Appendix C Connector PIN Layout
Field Description
1
1
90°
0° 180°
22
33
1
1. No beep.
2. Fast beep; from 95.0 to 99.5 gon and 105.0 to
100.5 gon.
3. Permanent beep; from 99.5 to 99.995 gon and
from 100.5 to 100.005 gon.
Off Sector Beep is deactivated.
Setout Beep On The instrument beeps when the distance from the cur-
rent position to the point to be staked is 0.5 m. The
closer the prism is to the point to be staked the faster
the beeps will be.
Off Beep is deactivated.
Screen ill. 20% to 100% Sets the screen illumination in 20% steps.
Crossh ill. Off to 100% Sets the illumination level of the crosshairs in 20%
steps.
Heating On The display heater is activated.
Off The display heater is deactivated.
☞
The display heater is automatically activated when the display illumination
is on and the instrument temperature is 5°C. This function is only availa-
ble for Zoom25.
Data Output Sets the location for data storage.
Int. Memory All data is recorded in the internal memory.
Interface Data is recorded via the serial interface or the USB
device port, depending on the port selected in the
COMMUNICATION SETTINGS screen. This Data
Output setting is only required if an external storage
device is connected and measurements are started at
the instrument with MEAS/REC or ALL. This setting is
not required if the instrument is totally controlled by a
data logger.
GSI-Format Sets the GSI output format.
GSI 8 81..00+12345678
GSI 16 81..00+1234567890123456
Mask Sets the GSI output mask.
Mask1 Pt, HA, VA, sDIST, ppm+mm, TgtHGT, Instr.h.
Mask2 Pt, HA, VA, sDIST, E, N, Z, TgtHGT.
Mask3 StationID, E, N, Z, Instr.h. (Station).
StationID, Ori, E, N, Z, Instr.h. (Station Result).
Pt, E, N, Z (Control).
Pt, HA, VA (Set Azimuth).
Pt, HA, VA, SD, ppm+mm, TgtHGT, E, N, Z (Measure-
ment).
Code Saving Sets if the codeblock is saved before or after the measurement. Refer to
"8.1 Coding".
Language Sets the chosen language. The current loaded language(s) are shown.
A selected language can be deleted by pressing DelLng. This function is
available if more than one language is installed, and the selected language
is not the chosen operating language.
Applications - Getting Started 37