Product Manual

Table Of Contents
5 Settings
5 Applications - Getting Started
5.1 General Settings
1. Select Settings from the MAIN MENU.
2. Select General from the Settings menu.
3. Press to scroll through the screens of available settings.
Field Description
Tilt Corr. Off Tilting compensation deactivated.
On Vertical angles refer to the plummet line and the hori-
zontal directions are corrected by the standing axis tilt.
For corrections depending on the HA Corr: setting,
refer to the table "Tilt and horizontal corrections".
If the instrument is used on an unstable base, for example a shaking plat-
form or ship, the compensator should be deactivated. This avoids the com-
pensator drifting out of it's measuring range and interrupting the measur-
ing process by indicating an error.
H.A. Corr. On Horizontal corrections are activated. For normal opera-
tion the horizontal correction should remain active.
Each measured horizontal angle will be corrected,
depending on the vertical angle.
For corrections depending on the Tilt Corr: setting,
refer to the table "Tilt and horizontal corrections".
Off Horizontal corrections are deactivated.
H.A. Incr. Right Set horizontal angle to clockwise direction measure-
ment.
Left Set horizontal angle to counter-clockwise direction
measurement. Counter-clockwise directions are dis-
played but are saved as clockwise directions.
V.A. Setting Sets the vertical angle.
Zenith
90°
270°
180°
45°
Zenith=0°; Horizon=90°.
Access
GENERAL SETTINGS
Settings 35