4.1 Instrument Setup
This topic describes an instrument setup over a marked ground point using the laser plummet. It
is always possible to set up the instrument without the need for a marked ground point.
Important features
It is always recommended to shield the instrument from direct sunlight and avoid uneven
temperatures around the instrument.
The laser plummet described in this topic is built into the vertical axis of the instrument. It
projects a red spot onto the ground, making it appreciably easier to centre the instrument.
The laser plummet cannot be used with a tribrach equipped with an optical plummet.
When setting up the tripod
pay attention to ensuring a
horizontal position of the tri-
pod plate. Slight corrections of
inclination can be made with
the foot screws of the tribrach.
Larger corrections must be
done with the tripod legs.
a
b
Loosen the clamping screws on the
tripod legs, pull out to the required
length and tighten the clamps.
a In order to guarantee a firm
foothold sufficiently press
the tripod legs into the
ground.
b When pressing the legs into
the ground note that the
force must be applied along
the legs.
Careful handling of tripod.
Check all screws and bolts for
correct fit.
During transport always use the
cover supplied.
Use the tripod only for survey-
ing tasks.
Description
Tripod