Product Manual
Table Of Contents
- 1 Safety Directions
- 2 Description of the System
- 3 User Interface
- 4 Operation
- 5 Settings
- 6 Tools
- 7 Functions
- 8 Coding
- 9 MapView Interactive Display Feature
- 10 Applications - Getting Started
- 11 Applications
- 12 Data Management
- 13 Calibration
- 14 Care and Transport
- 15 Technical Data
- 15.1 Angle Measurement
- 15.2 Distance Measurement with Reflectors
- 15.3 Distancer, Measurements without Reflectors (Reflectorless mode)
- 15.4 Distance Measurement Reflector (Long Range)
- 15.5 Conformity to National Regulations
- 15.6 General Technical Data of the Product
- 15.7 Scale Correction
- 15.8 Reduction Formulas
- 16 Software Licence Agreement
- 17 Glossary
- Appendix A Menu Tree
- Appendix B Directory Structure
- Appendix C Connector PIN Layout
Type Value
Type Li-Ion
Voltage 7.4 V
Capacity 4.4 Ah
Operating time approximately 16 hours
Based on a single measurement every 30 s at 25 °C.
Operating time may be shorter if battery is not new.
Temperature
Type Operating temperature Storage temperature
[°C] [°F] [°C] [°F]
Zoom instru-
ment
-20 to +50 -4 to +122 -40 to +70 -40 to +158
Battery -20 to +50 -4 to +122 -40 to +70 -40 to +158
Protection against water, dust and sand
Type Protection
Zoom instrument IP55 (IEC 60529)
Dust-proof and complete protection against contact and water
jets.
Humidity
Type Protection
Zoom instrument Max 95% non condensing.
The effects of condensation are to be effectively counteracted by
periodically drying out the instrument.
The following automatic corrections are made:
•
Line of sight error
•
Tilting axis error
•
Earth curvature
•
Standing axis tilt
•
Vertical index error
•
Refraction
•
Compensator index error
•
Circle eccentricity
15.7 Scale Correction
By entering a scale correction, reductions proportional to distance can be taken into account.
•
Atmospheric correction.
•
Reduction to mean sea level.
•
Projection distortion.
The slope distance displayed is correct if the scale correction in ppm, mm/km, which has been
entered corresponds to the atmospheric conditions prevailing at the time of the measurement.
Battery ZBA400
Environmental specifica-
tions
Automatic corrections
Use of scale correction
Atmospheric correction
132 Technical Data