Product Manual
Table Of Contents
- 1 Safety Directions
- 2 Description of the System
- 3 User Interface
- 4 Operation
- 5 Settings
- 6 Tools
- 7 Functions
- 8 Coding
- 9 MapView Interactive Display Feature
- 10 Applications - Getting Started
- 11 Applications
- 12 Data Management
- 13 Calibration
- 14 Care and Transport
- 15 Technical Data
- 15.1 Angle Measurement
- 15.2 Distance Measurement with Reflectors
- 15.3 Distancer, Measurements without Reflectors (Reflectorless mode)
- 15.4 Distance Measurement Reflector (Long Range)
- 15.5 Conformity to National Regulations
- 15.6 General Technical Data of the Product
- 15.7 Scale Correction
- 15.8 Reduction Formulas
- 16 Software Licence Agreement
- 17 Glossary
- Appendix A Menu Tree
- Appendix B Directory Structure
- Appendix C Connector PIN Layout
Beam interruptions, severe heat shimmer and moving objects within the beam path can result in
deviations of the specified accuracy.
Principle: Phase measurement
Type: Coaxial, visible red laser
Carrier wave: 658nm
Measuring system: Zoom25: Distance measurement system
using phase-shift principle with fre-
quency 320MHz
Zoom50: System analyser basis 100 MHz -
150 MHz
15.3 Distancer, Measurements without Reflectors (Reflectorless
mode)
N5/A5 (without reflector)
Kodak Gray Card Range D Range E Range F
[m] [ft] [m] [ft] [m] [ft]
White side, 90% reflective 250 820 400 1312 >500 >1640
Grey side, 18% reflective 100 330 150 490 >250 >820
A10 (without reflector)
Kodak Gray Card Range D Range E Range F
[m] [ft] [m] [ft] [m] [ft]
White side, 90% reflective 600 1970 800 2630 £1000 £3280
Grey side, 18% reflective 300 990 400 1310 £500 £1640
Range of Measurement: 1.5m to 1200m
Display unambiguous: up to 1200m
Range Description
D Object in strong sunlight, severe heat shimmer
E Object in shade, or overcast
F Underground, night and twilight
Standard
measuring
ISO 17123-4 Measure time,
typical [s]
Measure time,
maximum [s]
0m - 500m 2mm + 2ppm 3 - 6 15
>500m 4mm + 2ppm 3 - 6 15
Beam interruptions, severe heat shimmer and moving objects within the beam path can result in
deviations of the specified accuracy.
Characteristics
Range
Atmospheric conditions
Accuracy
Technical Data 127