Product Manual
Table Of Contents
- 1 Safety Directions
- 2 Description of the System
- 3 User Interface
- 4 Operation
- 5 Settings
- 6 Tools
- 7 Functions
- 8 Coding
- 9 MapView Interactive Display Feature
- 10 Applications - Getting Started
- 11 Applications
- 12 Data Management
- 13 Calibration
- 14 Care and Transport
- 15 Technical Data
- 15.1 Angle Measurement
- 15.2 Distance Measurement with Reflectors
- 15.3 Distancer, Measurements without Reflectors (Reflectorless mode)
- 15.4 Distance Measurement Reflector (Long Range)
- 15.5 Conformity to National Regulations
- 15.6 General Technical Data of the Product
- 15.7 Scale Correction
- 15.8 Reduction Formulas
- 16 Software Licence Agreement
- 17 Glossary
- Appendix A Menu Tree
- Appendix B Directory Structure
- Appendix C Connector PIN Layout
15 Technical Data
15.1 Angle Measurement
Available angu-
lar accuracies
Standard deviation HA,
VA, ISO 17123-3
Display resolution
["] [mgon] ["] [°] [mgo
n]
[mil]
1 0.3 1 0.0001 0.1 0.01
2 0.6 1 0.0001 0.1 0.01
5 1.5 1 0.0001 0.1 0.01
Absolute, continuous, diametric. Updates each 0.1 to 0.3 s.
15.2 Distance Measurement with Reflectors
Reflector Range A Range B Range C
[m] [ft] [m] [ft] [m] [ft]
Standard prism 1800 6000 3000 10000 3500 12000
3 prisms
N5 2300 7500 3000 10000 3500 12000
A5/A10 2300 7500 4500 14700 5400 17700
Reflector foil
60 mm x 60 mm
150 500 250 800 250 800
Shortest measuring distance: 1.5m
Range Description
A Strong haze, visibility 5km; or strong sunlight, severe heat shim-
mer
B Light haze, visibility about 20km; or moderate sunlight, slight heat
shimmer
C Overcast, no haze, visibility about 40km; no heat shimmer
Accuracy refers to measurements to standard reflectors.
EDM measuring mode Standard deviation
ISO17123-4
Measurement time, typical
[s]
Zoom25 Zoom50
IR-Default 2mm + 2ppm 2.4 2.4
IR-Quick 3mm + 2ppm 2.0 1.0
IR-Continuous 3mm + 2ppm 0.33 0.3
Foil 3mm + 2ppm 2.4 2.4
Accuracy
Characteristics
Range
Atmospheric conditions
Accuracy
126 Technical Data