Product Manual

Table Of Contents
Field Description
A message will appear if the tolerances defined in the Traverse
configuration are exceeded.
Next step
Close the traverse by selecting Close in the Sight Foresight! screen after a backsight point
measurement, but before the foresight point measurement.
11.14.5 Closing a Traverse
Close the traverse by selecting Close in the Sight Foresight! screen after a backsight point
measurement, but before the foresight point measurement.
Field Description
F1...at Known Station
to Known Closing Point
To close a traverse at a known station to a known closing point.
Use when setup on the closing station, and the coordinates for
the station and the closing point are known.
If this method is chosen a distance measurement is
mandatory.
1. Input the data for both points.
2. Measure to the closing point.
3. The results are displayed.
F2...to Known Closing
Point
To close a traverse to a known closing point.
Use when setup on an unknown station and only the coordinates
of the closing point are known.
1. Input the data for the point.
2. Measure to the closing point.
3. The results are displayed.
F3...at Known Station
Only
To close a traverse at a known station only.
Use when setup on the closing station and the coordinates for it
are known.
1. Input the data for the closing station.
2. The results are displayed.
F4...Leave Open To leave the traverse open. There is no last traverse station.
1. The results are displayed.
Select an option, from the Close Traverse... menu to proceed to the Traverse Results screen.
Field Description
Traverse ID Name of the traverse.
Start Stn. Point ID of the start station.
End Stn. Point ID of the end station.
No.of Stn. Number of stations in the traverse.
Total Dist. Total distance of the traverse.
1D Accuracy Accuracy in 1D
1/(
Length of Traverse
)
Height Misclosure
Access
Close Traverse...
Next step
Traverse results
110 Applications