Appendix E – OTT SVR 100 Operating Program
The "OTT SVR 100 Operating Program" PC software is available for service pur-
poses. You can use this software to establish a temporary connection to the OTT
SVR 100 via the RS-232 interface and
!
set OTT SVR 100 operating parameters
!
perform a firmware update
!
start a continuous measurement and represent flow velocity measured values
graphically
If necessary, download the latest version of the operating program (setup file)
from "www.ott.com/resources". The user interface language is English.
Required equipment:
!
PC (desktop or laptop; operating system: Microsoft Windows 7 or later)
with RS-232- or USB interface
!
for PC with USB interface: RS-232/USB interface adapter
1)
!
RS-232 connecting cable
1)
!
(temporary) power supply for the OTT SVR 100
1)
S
ee Chapter 2, Accessories
How to install the OTT SVR 100 Operating Program
" Launch "Setup-SVR100-Configurator-x.x.x.exe" ➝ the "OTT SVR100 Con -
figurator Setup Wizard" (installation program) opens.
" Perform the actions displayed on the screen.
How to use the OTT SVR 100 Operating Program
" Connect the OTT SVR 100 to the PC:
OTT SVR 100 connecting cable (TxD: green, RxD: yellow, Signal GND: grey)
↔ RS-232 connecting cable (TxD: brown (2), RxD: red (3), GND: yellow (5))
↔ RS-232 interface (or USB interface with interface adapter) on PC.
" Connect OTT SVR 100 to power supply (+9 … +27 V
DC
: brown; GND: white).
" Launch the OTT SVR 100 Operating Program (file "OTT SVR100 Configu -
rator.exe")
" Establish a connection: Select "Home" tab, set "COM Port used" and click
on "Connect" ➝ The operating program establishes a connection to the
OTT SVR 100.
Fig. E1: Establishing a connection to the
OTT SVR 100 via the RS-232 interface.
32