radar level meter information and operating parameters. Some of these parameters can
be changed by editing the values directly inside the Radar Module Info pane. The following
information is displayed:
Firmware version
the version of the firmware running in the radar sensor device
Level correction
correction in meters to be added to the detected level
Deadzone minimum
minimum detected distance
Deadzone maximum
maximum detected distance
Filter length
if moving average filter is used, select the averaging window length
Amplitude threshold
minimum spectrum amplitude necessary for peak detection
RX gain
the current gain value of the radar signal amplifier
IR constant
if IR is used, this value is used for the IR filter
Serial baud rate
the communication baudrate used for serial communication
RS485 baud rate
the communication baudrate used for RS485 communication
RS485 parity
parity used on the RS485 bus
RS485 stopbits
stopbits used on the RS485 bus
Modbus address
device address on the RS485 bus
Water level
water level in meters
Average water level
average water level in meters, using filter length
The second pane (in the right part of the window) displays the history graph