User's Manual

LX-80 User Manual
Page 24 of 32
Fun
Data Addr
Data Length
Data Range
Details
0x0006
2 bytes
0 → no parity
1 stopbit
1 → no parity
2 stopbits
2 → odd parity
1 stopbit
3 → odd parity
2 stopbits
4 → even parity
1 stopbit
5 → even parity
2 stopbits
default → even parity
1 stopbit
RS-485 parity and stopbits
0x0007
2 bytes
1-65535
SDI-12 ID
0x000A
2 bytes
900 - 65535
Device type;
LX-80 999, 998, 997
0x000B
2 bytes
1 200
default: 24
Number of frames for
window filtering
0x000C
2 bytes
1 65535
default: 0
Minimum spectrum
amplitude threshold, used
for detecting peaks
0x000D
2 bytes
0 device range
default → 0
Deadzone minimum in
selected unit
0x000E
2 bytes
0 device range
default device range
[unit]
Deadzone maximum in
selected unit
0x000F
2 bytes
0 device range
default 0
4-20mA minimum value in
selected unit
0x0010
2 bytes
0 device range
default → device range
[unit]
4-20mA maximum value in
selected unit
0x0011
2 bytes
0 device range
[unit]
Level measurement offset
0x0012
2 bytes
0 1000
IR filter constant





0x0013
2 bytes
0 34
RX gain
0x0014
2 bytes
1 3
Active TX antenna
0x0015
2 bytes
2 printable characters
Serial number[0-1]
0x0016
2 bytes
2 printable characters
Serial number[2-3]
0x0017
2 bytes
2 printable characters
Serial number[4-5]