Changes the minimum spectrum amplitude threshold for peak to be detected. Peaks under this
value will not be detected. Accepts integer values.
Change deadzone settings
#set_deadzone_min=<0->
#set_deadzone_max=<0->
Changes the deadzone of the sensor. Objects under deadzone min and over deadzone max will
not be registered. Accepted values are floating point using decimal point in selected unit.
Change 4-20mA settings
#set_analog_min=<0->
#set_analog_max=<0->
Changes the range in which 4-20mA output reports values of the sensor. Minimum value is
reported as 4mA and maximum value is reported as 20mA. Both values are accepted as floating point,
in selected unit.
Change sensor height
#set_sensor_height=<>
Set sensor height relative to the bottom of the riverbed. The sensor will output relative
measurement of the actual water level based on its height above the riverbed.
#set_staff_gauge =<>
Set sensor height relative to the measurement using staff gauge. The sensor will output relative
measurement of the actual water level based on its height above the riverbed.